Get complete information related to latest Milk Storage Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Milk Storage Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Milk Storage Tank Tenders.
Tender For bid to ras supply of storage 300 tb , meta data storage san storage msa 2060 , fc switch , usb powered external hard disk drives 4 tb ssd , cables and accessories , server , fault tolerance server , smart 42 u rack with access control and 15kw cooling redundant fire suppression system camera rodent repellent system to house servers and switches , 10 g switches and routers , layer 3 switch , 10 g firewall , firewall , workstation with dual monitor , miscellaneous items installation and commissioning charges , resident engineer cost per year , windows server license latest , ms sql server , nas 500tb , management device , color ink tank printer , printer mfd a3 , color laser printer a4
Tender For corrigendum : water cooler with ro (reverse osmosis included membrane, carbon filter sediment filter, primary filter specifications input water tds allow to systen- 2000ppm (max) input water hardness (in ppm)- 500. material of water tankstorage ss304 or superior. storagetank capacity up to float valve level (in ltrs)-80 (minimum). stage of purification- 4 (minimum). no. of ro membrane-01 (minimum), ro membrane rating -150 gpd (minimum), particular filter size (minimum)-10 inch. activate carbon filter size (minimum)- 10 inch filteration water capacity -150 ltrs/hr no. of cold water faucets-02 nos. cooling capacity at comfort level- 60 ltrs/hrs (minimum) power supply 230 volts auto flush at evey start & stop and every one hour for 1 minutes with auto cut off/on type- floor mounted make aemric/zero b/voltas/blue star or another reputed make (as per specifications attached) ]
Tender For water cooler with ro (reverse osmosis included membrane, carbon filter sediment filter, primary filter specifications input water tds allow to systen- 2000ppm (max) input water hardness (in ppm)- 500. material of water tankstorage ss304 or superior. storagetank capacity up to float valve level (in ltrs)-80 (minimum). stage of purification- 4 (minimum). no. of ro membrane-01 (minimum), ro membrane rating -150 gpd (minimum), particular filter size (minimum)-10 inch. activate carbon filter size (minimum)- 10 inch filteration water capacity -150 ltrs/hr no. of cold water faucets-02 nos. cooling capacity at comfort level- 60 ltrs/hrs (minimum) power supply 230 volts auto flush at evey start & stop and every one hour for 1 minutes with auto cut off/on type- floor mounted make aemric/zero b/voltas/blue star or another reputed make (as per specifications attached) ]
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For supply of 2000 l polyethylene water storagetank with double layer approved brand , 60ltr cooling capacity 120ltr storage capacity water cooler , cpvc pipes , drain pipe with 40mm dia cpvc pipes with all accessories and insulation with 6mm thick , electrical point wiring for cooler , mazdoor to carry all material , providing and fixing of ms grill
Tender For supply of portable air cooler 230 volt 50 hz, air delivery 18000 cubic meter/hour , tank capacity 200 litres, powerful 21m air throw for faster cooling, 3 side high efficiency honeycomb pads, robust weather resistant body for long life, fully closable horizontal louvers, powerful 3 speed fan, easily removable and cleanable cooling pads, 3 side dust filters for pure healthy air, float valve for auto water filling, lockable heavy duty wheels, low power consumption-575 watts, fiber body length 1125mm, breadth 725mm, height 1790mm. make symphony, havells, crompton, bajaj or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of operation and routine maintenance of water cooled chiller hvac system , 3x500tr i/c ahus and cooling tower , vrv system at various locations inside the terminal building and medical centre , various pumps and other installation of wtp and stp , ro , water coolers and split/tower/window ac units at various locations , water fountains inside the terminal building , ensuring serviceability/ satisfactory working condition of the systems i/c maintenance of records/logbook/ documents etc. on all days i/c saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following min. no. of man power- (a) supervisor (highly skilled) - 01 no. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 03 nos. (ie 01 no. round the clock on all days in every week for operation of chiller , reliever shall be provided on weekly off). (c) ac technician / mechanic (skilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of r.o. , water coolers and split/tower/window ac units at various locations , reliever shall be provided on weekly off). (d) asst. ac mechanic cum operator (semi skilled) - 09 nos. (i.e. 01 no. round the clock for operation of ahu , 01 no. round the clock for operation and maintenance of wtp , 01 no. round the clock for operation of stp on all days in every week , reliever shall be provided on weekly off). (e) asst. ac mechanic cum operator (semi skilled) - 01 no. (i.e. 01 no. in general shift for maintenance of stp , reliever shall be provided on weekly off). (f) helper (unskilled) - 03 nos. (i.e. 01 no. round the clock on all days in every week for hvac , reliever shall be provided on weekly off). (g) helper (unskilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of ro , water coolers and split/tower/window ac units at various locations , reliever shall be provided on weekly off). , operation and routine maintenance of vrv system at ats cum technical block and precision air conditioning system at new mssr building including maintenance of records/logbook/ documents etc. on all days including saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following minimum number of man power - (a) supervisor (highly skilled) - 01 nos. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 01 nos. (i.e. 01 no. in general shift on all days in every week for operation and routine maintenance of vrv system at ats cum technical block and pac system at new mssr building , reliever shall be provided on weekly off). (c) asst. ac mechanic cum operator (semi skilled) - 06 nos. (i.e. 01 no. round the clock for operation and routine maintenance of vrv system in ats block and 01 no. round the clock for operation and routine maintenance of pac system at new mssr building on all days in every week , reliever shall be provided on weekly off). , operation and routine maintenance of packaged air conditioning system at old mssr building including maintenance of records/logbook/ documents etc. on all days including saturday , sunday and holidays as per tender specifications , terms and conditions by supplying of following minimum number of man power - (a) asst. ac mechanic cum operator (semi skilled) - 03 nos. (i.e. 01 no. round the clock for operation and routine maintenance of packaged air conditioning system at old mssr building on all days in every week , reliever shall be provided on weekly off). , annual all inclusive comprehensive maintenance contract of central ac plant (hvac) for 3x500tr (make- mcquay) centrifugal chiller type comprising of 3 no. cooling tower (make- advance) and 1no cooling tower (make- bell) with make-up tank , associated pumps as condenser water pump - 03 no(40hp) , primary water pump - 03no (25hp) , secondary water pump 12 hr - 03 no.